4.7 Mounting and removal the xREM 80 SmylTR module
The module is supplied with the IPDP SLIM panel, where it can occupy space of a single
push button space in a predefined position. For manipulation with the devices please follow
the instructions in the user’s guide to the IPDP SLIM panel.
5 Setting parameters of the reader module
5.1 Configurable parameters
Configurable parameters
Parameter Possible range Default setting
Door lock release time
0 255 s
7 s
Door lock control setting Direct / reverse Direct
Door lock relay function setting Standard / toggle / pulse Standard
Permanent door lock release according to
a time schedule
Never / Schedule index Never
Door lock status indication YES / NO NO
Acoustic signal of door lock release YES / NO YES
Door ajar time
0 255 s
20 s
Second input configuration
REX button / handle contact
/ external tamper / tamper /
disabling function
REX button
Acoustic signalization time - Tamper
0 255 s
30 s
Acoustic signalization time - Forced door
0 255 s
30 s
Acoustic signalization time – Door ajar
0 255 s
0 s
Acoustic signalization time – APB alarm
0 255 s
0 s
Signalization time – Card alarm
0 255 s
30 s
Antipassback function setting
See chapter 6.10
Disabled
Automatic summer time adjustment
YES / NO YES
Saving events in
the module’s
archive
Door opened Enabled / Disabled Enabled
Door closed Enabled / Disabled Enabled
Input 2 On Enabled / Disabled Enabled
Input 2 Off Enabled / Disabled Enabled
Strike released Enabled / Disabled Enabled
Strike closed Enabled / Disabled Enabled
Table 9: Configurable parameters
5.2 Reader module parameters setting
Detailed instructions for setting reader module parameters are described in the APS
Reader configuration program user’s guide available at the address
http://www.techfass.cz/files/m_aps_miniplus_reader_en.pdf.