Parameter Value Meaning Basic
55 z
time before dialing
1
z – time [sec] after guard lifting up before dialing [range 1-5]. This time is
different for each exchange, but most central exchanges usually manage
to process dialing up to 2 seconds after line lifting up.
List of related parameters: 8# 85
Parameter Value Meaning Basic
56 hh
number of rings before hanging up
12
h – after finishing the dialing it calculates number of KVT (ringing tones). If
the number exceeds h value, it will hang up [range 04-99]. The dialing is
repeated in case, when the dialing mode of 2 groups is set.
List of related parameters: 47 8# 85
Parameter Value Meaning Basic
57 t
DTMF tone duration (tone) choice
5 (100ms)
58 m
gap duration among DTMF tones
5 (100ms)
59 f
Flash duration
1 (100ms)
50 p
pause duration / interdigit gap
8 (800ms)
t – DTMF tone duration is determined per formula:
(entered number + 5) x 10 = tone duration [ms]
[range 1-0 i.e. 60-150ms]
m – gap duration among DTMF tones is determined per formula:
(entered number + 5) x 10 = gap duration [ms]
[range 1-0 i.e. 60-150ms]
f – Flash duration is determined per formula:
entered number x 100 = Flash duration [ms]
[range 1-6 i.e. 100-600ms]
p – pause duration is determined per formula:
entered number x 100 = pause duration [ms]
[range 5-0 i.e. 500-1000ms]
– p time is simultaneously the duration of interdigit gap at pulse dialing.
List of related parameters: 1 2 41 8# 85